top of page

Power Output Panel  - Docking Station - Tap Box
Single-Phase 200A
MTC 6001 OESKv

Roam's MTC® 6001 OESKv series ("v" = Voltage Code) of Power Output Panels provides a rugged and cost-effective exterior connection point for high-capacity external power loads. These Power Output Panels use E1016 (J-Series/16 Series) Female Cam-Lok* brand connectors and are part of Roam's UL Listed (US & Canada) series of single-phase power output panels. 

 

The standard in safety and outdoor reliability, Roam's Power Output Panels makes connecting building (line) power to external or internal loads fast, easy, and most importantly—safe. 

 

Like the rest of Roam's line of Power Output Panels (also known as Outlet Panels, Docking Stations, or Tap Boxes), the MTC 6001 OESKv panels offers a safe, secure power output connection point for external loads such as lighting, mobile equipment, booths, test load banks, or entertainment venue power. The MTC 6001 OESKv line is part of Roam's UL Listed (US & Canada) series of single-phase Power Output Panels. Roam uses genuine Cooper Crouse-Hinds Cam-Lok brand connectors. Similar compatible connectors are sometimes referred to as "Cam-Lock" connectors by their manufacturers, distributors, and/or users.

• Single-phase power, at up to 200A

• 240 VAC, 480 VAC, & 600 VAC rated panels

• Spot-welded Galvanneal steel construction

• Custom labels & configurations available

• Brown-Orange-Yellow connectors at 480VAC

• Corrosion-resistant powder coating

• UV-resistant four color labels

• Built to NEMA 3R standard

• Internal and external grounding studs

• Four Female E1016 Cam-Lok connectors

MTC 6001 OESK2
MTC 6001 OESK2 - 200A/240VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK2 - UL/cUL Listed

MTC 6001 OESK2 - 200A/240VAC
Single-Phase  - Power Output Panel - Open/240VAC

MTC 6001 OESK2
MTC 6001 OESK2 - 200A/240VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK2 - UL/cUL Listed

MTC 6001 OESK2 - 200A/240VAC
Single-Phase  - Power Output Panel - Closed/240VAC

Connections

Roam's MTC 6001 OESKv 200 Amp Power Output Boxes accept either #2 to 2/0 or 2/0 to 4/0 cables via Cam-Lock plugs on the generator cable side, and from 1/0 to 4/0 cables on the internal wireway side. 

Voltages up to 600VAC

Roam offers MTC 6001 OESKv Power Output Panels in models that support up to 240 VAC (120v, 208v, 230v, 240v)—MTC 6001 OESK2, up to 480 VAC (277v, 330v, 440v, 480v)—MTC 6001 OESK4-BOY, and up to 600 VAC (575v, 577v, 600v)—MTC 6001 OESK6, which are UL Listed and cUL Listed (Canada) at those voltage levels. Brown-Orange color coding (for labels, Cam-Locks, & Cam-Lock spring caps) is normally used for most 480 VAC applications.

MTC 6001 OESK4-BOY
MTC 6001 OESK4-BOY - 200A/480VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK4-BOY - UL/cUL Listed

MTC 6001 OESK4 - BOY- 200A/480VAC - Single-Phase Output Gen Box - Open

MTC 6001 OESK4-BOY
MTC 6001 OESK4-BOY - 200A/480VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK4-BOY - UL/cUL Listed

MTC 6001 OESK4 - BOY- 200A/480VAC - Single-Phase Output Gen Box - Closed

MTC 6001 OESK6
MTC 6001 OESK6 - 200A/600VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK6 - UL/cUL Listed

MTC 6001 OESK6 - 200A/600VAC
Single-Phase - Power Output Panel - Open/600VAC

MTC 6001 OESK6
MTC 6001 OESK6 - 200A/600VAC - 1-Phase - Power Output Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock Power Output Panel - MTC6001OESK6 - UL/cUL Listed

MTC 6001 OESK6 - 200A/600VAC
Single-Phase - Power Output Panel - Closed/600VAC

Canadian Color Coding Available

Any Roam panels with power connectors normally color coded (for Cam-Locks, Spring Caps, and Labels) as L1=Black & L2=Red are also available in the typical Canadian color coding format of L1=Red & L2=Black. If you need to order a unit with the Canadian color scheme, just add a "-CAN" to the end of the Model Number. If the loads you are connecting to use the US color coding (L1=Black & L2=Red), then you may want the standard US color system (so long as local electrical codes allow).

Model Numbers & Options

The "v" in the part number represents a code of either 2 (for up to 240 VAC panels), 4 (for up to 480 VAC panels), or 6 (for up to 600 VAC panels).

unnamed.png

UL 891 Listed—US & Canada

bottom of page