top of page

Power Input Panel - Tap Box - Inlet Box 
Three-Phase 400A 
MTC 6001 IESHKv-W

Roam's MTC® 6001 IESHKv-W series ("v" = Voltage Code) of Power Input Panels provides a rugged and cost-effective exterior connection point for temporary power input to trailers, buses, or temporary structures. These Power Input Panels use E1016 (J-Series/16 Series) male Cam-Lok* brand connectors and are part of Roam's UL Listed (US & Canada) series of single-phase power input panels. 

 

The new standard in safety and outdoor reliability, Roam's line of Power Input Boxes (also known as Tap Boxes or Inlet Boxes) makes connecting a temporary power input to line power output from a building fast, easy, and most importantly—safe. Roam uses genuine Cooper Crouse-Hinds Cam-Lok brand connectors. Similar compatible connectors are sometimes referred to as "Cam-Lock" connectors by their manufacturers, distributors, and/or users.

• Single-phase power, at up to 400A

• 240 VAC, 480 VAC, & 600 VAC rated panels

• Spot-welded Galvanneal steel construction

• Custom labels & configurations available

• Brown-Orange-Yellow connectors at 480VAC

• Corrosion-resistant powder coating

• UV-resistant four color labels

• Built to NEMA 3R standard

• Internal and external grounding studs

• Four Male E1016 Cam-Lok connectors

MTC 6001 IESHK2-W
MTC 6001 IESHK2-W - 400A/240VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Wide Form Factor - Single-Phase - Power Input Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK2-W - UL/cUL Listed

MTC 6001 IESHK2-W - 400A/240VAC
Single-Phase - Power Input Panel - Open/240VAC

MTC 6001 IESHK2-W
MTC 6001 IESHK2-W - 400A/240VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Input Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK2-W - UL/cUL Listed

MTC 6001 IESHK2-W - 400A/240VAC
Single-Phase - Power Input Panel - Closed/240VAC

Connections

Roam's MTC 6001 IESKv 200 Amp Power Input Boxes accept either #2 to 2/0 or 2/0 to 4/0 cables via Cam-Lock plugs on the generator cable side, and from 1/0 to 4/0 cables on the internal wireway side. 

Voltages up to 600VAC

Roam offers MTC 6001 IESHKv-W Power Input Panels in models that support up to 240 VAC (120v, 208v, 230v, 240v)—MTC 6001 IESHK2-W, up to 480 VAC (277v, 330v, 440v, 480v)—MTC 6001 IESHK4-BOY-W, and up to 600 VAC (575v, 577v, 600v)—MTC 6001 IESHK6-W, which are UL Listed and cUL Listed (Canada) at those voltage levels. Brown-Orange color coding (for labels, Cam-Locks, & Cam-Lock spring caps) is normally used for most 480 VAC applications.

MTC 6001 IESHK2-BOY-W
MTC 6001 IESHK4-BOY-W - 400A/480VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Wide Form Factor - Single-Phase - Power Input Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK4-BOY-W - UL/cUL Listed

MTC 6001 IESHK4-BOY-W - 400A/480VAC
Single-Phase - Power Input Panel - Open/480VAC

MTC 6001 IESHK2-BOY-W
MTC 6001 IESHK4-BOY-W - 400A/480VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Input Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK4-BOY-W - UL/cUL Listed

MTC 6001 IESHK4-BOY-W - 400A/480VAC
Single-Phase - Power Input Panel - Closed/480VAC

MTC 6001 IESHK6-W
MTC 6001 IESHK6-W - 400A/600VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Wide Form Factor - Single-Phase - Power Input Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK6-W - UL/cUL Listed

MTC 6001 IESHK6-W - 400A/600VAC
Single-Phase -Power Input Panel - Open/600VAC

MTC 6001 IESHK6-W
MTC 6001 IESHK6-W - 400A/600VAC - 1-Phase - Power Input Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Power Input Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 400 Amp - Door Open - Wide Form Factor - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Power Input Panel - MTC6001IESHK6-W - UL/cUL Listed

MTC 6001 IESHK6-W - 400A/600VAC
Single-Phase -Power Input Panel - Closed/600VAC

Canadian Color Coding Available

Any Roam panels normally color coded (for Cam-Locks, Spring Caps, and Labels) as L1=Black & L2=Red are also available in the typical Canadian color coding format of L1=Red & L2=Black. If you need to order a unit with the Canadian color scheme, just add a "-CAN" to the end of the Model Number. If you are connecting the Power Input Panel to a power source that uses the US color coding (L1 = Black & L2 = Red), then you may want the standard US color coding (so long as local electrical codes allow).

Spring Caps

These units are also available without Cam-Lock Spring Caps. Roam strongly recommends the Spring Cap version to help protect the Cam-Lock connectors' brass conductors from insects, spider webs, dust, and corrosion. Omit the "K" from the model number to order a version of this panel without Spring Caps.

Model Numbers & Options

The "v" in the part number represents a code of either 2 (for up to 240 VAC panels), 4 (for up to 480 VAC panels), or 6 (for up to 600 VAC panels).

unnamed.png

UL 1008 Listed—US & Canada
All MTS Panels—Except for Service Entry rated panels.
Service Entry rated panels are not cUL Listed.

bottom of page