Three-Phase 1200A
MTC 6003 OES12KvB

Supporting up to 1200 Amps, Roam's MTC® 6003 OES12KvB series ("v" = Voltage Code) of Power Output Panels provides a rugged and cost-effective, exterior connection point for high-capacity external power loads. Roam's 1200A Power Output Panels use E1016 (J-Series/16 Series) Female Cam-Lok* connectors in three rows of 400A (max) connectors bus-barred together allows the panel to support up to 1200A.

 

The standard in safety and outdoor reliability, Roam's line of Power Output Panels makes connecting building (line) power to external or internal loads fast, easy, and most importantly—safe. 

 

Like the rest of Roam's line of Power Output Panels (also known as Outlet Panels, Docking Stations, or Tap Boxes), the MTC 6003 OES12KvB series offers a safe, secure power output connection point for external loads such as lighting, mobile equipment, booths, test load banks, or entertainment venue power. The MTC 6003 OES12KvB line is part of Roam's UL Listed (US & Canada) series of three-phase Power Output Panels. Roam uses genuine Cooper Crouse-Hinds Cam-Lok* brand connectors. Similar compatible connectors are sometimes referred to as "Cam-Lock" connectors by their manufacturers, distributors, and/or users.

• Corrosion-resistant powder coating

• UV-resistant four color labels

• Built to NEMA 3R standard

• Internal and external grounding studs

• Fifteen Female E1016 Cam-Lock connectors

• Three-phase power at up to 800 Amps
• 240 VAC, 480 VAC, & 600 VAC rated panels
• Spot-welded Aluminum construction
• Custom labels & configurations available
• Brown-Orange-Yellow connectors at 480VAC

MTC 6003 OES12K2B
MTC 6003 OES12K2B - 1200A/240VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K2B - UL/cUL Listed

MTC 6003 OES12K2B - 1200A/240VAC
Three-Phase - Power Output Panel - Open/240VAC

MTC 6003 OES12K2B
MTC 6003 OES12K2B - 1200A/240VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K2B - UL/cUL Listed

MTC 6003 OES12K2B - 1200A/240VAC
Three-Phase - Power Output Panel - Closed/240VAC

Connections

Roam's MTC 6003 OES12KvB 1200 Amp Power Output Panels accept either #2 to 2/0 or 2/0 to 4/0 cables via Cam-Lock plugs on the output cable side, and from #2 AWG to 600MCM cables on the internal wireway side. The wireway connection supports up to dual 600MCM cables (via bolted on lugs) on internal bus bars.

Voltages up to 600VAC

Roam offers the MTC 6003 OES12KvB Power Output Panel in models that support up to 240 VAC (120v, 208v, 230v, 240v)—MTC 6003 ES12K2B, up to 480 VAC (277v, 330v, 440v, 480v)—MTC 6003 OES12K4B-BOY, and up to 600 VAC (575v, 577v, 600v)—MTC 6003 OES12K6B. All of the 1200A panels are UL Listed and cUL Listed (Canada) at those voltage levels. Brown-Orange-Yellow color coding (for labels, Cam-Locks, & Cam-Lock spring caps) is normally used for most 480 VAC applications.

MTC 6003 OES12K4B-BOY
MTC 6003 OES12K4B-BOY - 1200A/480VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K4B-BOY - UL/cUL Listed

MTC 6003 OES12K4B-BOY - 1200A/480VAC
Three-Phase - Power Output Panel - Open/480VAC

MTC 6003 OES12K4B-BOY
MTC 6003 OES12K4B-BOY - 1200A/480VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K4B-BOY - UL/cUL Listed

MTC 6003 OES12K4B-BOY - 1200A/480VAC
Three-Phase - Power Output Panel - Closed/480VAC

MTC 6003 OES12K6B
MTC 6003 OES12K6B - 1200A/600VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K6B - UL/cUL Listed

MTC 6003 OES12K6B - 1200A/600VAC
Three-Phase - Power Output Panel - Open/600VAC

MTC 6003 OES12K6B
MTC 6003 OES12K6B - 1200A/600VAC - 3-Phase Power Output Panel - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K6B - UL/cUL Listed

MTC 6003 OES12K6B - 1200A/600VAC
Three-Phase - Power Output Panel - Closed/600VAC

Canadian Color Coding Available

Any Roam panels with power connectors normally color coded (for Cam-Locks, Spring Caps, and Labels) as L1=Black, L2=Red, & L3=Blue, are also available in the typical Canadian color coding format of L1=Red, L2=Black, & L3=Blue. If you need to order a unit with the Canadian color scheme, just add a "-CAN" to the end of the Model Number. If the loads you are connecting the Power Output Panel to use the US color coding (L1=Black, L2=Red, L3=Blue), then you may want the standard US color system (so long as local electrical codes allow).

No Neutral Options Available

Roam's 1200A Power Output Panels (Boxes) can also be ordered with no neutral connection for site and generator configurations designed for just Ground, L1, L2, and L3 cables. The "No Neutral" versions of these panels are also UL Listed and cUL Listed (Canada). To order a panel without a neutral connector just add a "-NN" to the end of the Model Number. The "No Neutral" panels use only four sets of three Cam-Lock connectors bus-barred together (a set of three for Ground, a set of three for L1, a set of three for L2, and a set of three for L3) for a total of twelve connectors.

MTC 6003 OES12K2B-NN
MTC 6003 OES12K2B-NN - 1200A/240VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K2B-NN - UL/cUL Listed

MTC 6003 OES12K2B-NN - 1200A/240VAC
Three-Phase - Power Output Panel
No Neutral - Open/240VAC

MTC 6003 OES12K2B-NN
MTC 6003 OES12K2B-NN - 1200A/240VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K2B-NN - UL/cUL Listed

MTC 6003 OES12K2B-NN - 1200A/240VAC
Three-Phase - Power Output Panel
No Neutral - Closed/240VAC

MTC 6003 OES12K4B-NN-BOY
MTC 6003 OES12K4B-NN-BOY - 1200A/480VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K4B-NN-BOY - UL/cUL Listed

MTC 6003 OES12K4B-NN-BOY - 1200A/480VAC
Three-Phase - Power Output Panel
No Neutral - Open/480VAC

MTC 6003 OES12K4B-NN-BOY
MTC 6003 OES12K4B-NN-BOY - 1200A/480VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K4B-NN-BOY - UL/cUL Listed

MTC 6003 OES12K4B-NN-BOY - 1200A/480VAC
Three-Phase - Power Output Panel
No Neutral - Closed/480VAC

MTC 6003 OES12K6B-NN
MTC 6003 OES12K6B-NN - 1200A/600VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Open - Three-Phase Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K6B-NN - UL/cUL Listed

MTC 6003 OES12K6B-NN - 1200A/600VAC
Three-Phase - Power Output Panel
No Neutral - Open/600VAC

MTC 6003 OES12K6B-NN
MTC 6003 OES12K6B-NN - 1200A/600VAC - 3-Phase Power Output Panel - Connection Panel - Tap Box - Docking Station - No Neutral - Bus Barred - Up to 600MCM Cable - Front View - Door Closed - Three-Phase Power Output Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - Door Open - Showing E1016 (J-Series/16-Series) Female Cam-Lok Connectors - Cam-Lock - MTC6003OES12K6B-NN - UL/cUL Listed

MTC 6003 OES12K6B-NN - 1200A/600VAC
Three-Phase - Power Output Panel
No Neutral - Closed/600VAC

Model Numbers & Options

The "v" in the part number represents a code of either 2 (for up to 240 VAC panels), 4 (for up to 480 VAC panels), or 6 (for up to 600 VAC panels).

unnamed.png

UL 891 Listed—US & Canada