top of page

Generator Interface Panel - Tap Box - Inlet Box - Docking Station - Gen Box 
Single-Phase 200A
MTC 6001 ESKv

Roam's MTC® 6001 ESKv series ("v" = Voltage Code) of Generator Interface Panels (Generator Connection Boxes) provide a rugged and cost-effective exterior connection point for emergency power. These Generator Interface Panels use E1016 (J-Series/16 Series) Male Cam-Lok* brand connectors and are part of Roam's UL Listed (US & Canada) series of single-phase generator interface panels. 


The standard in safety and outdoor reliability, Roam's line of Generator Interface Panels makes connecting a portable generator to your site fast, easy, and most importantly—safe. Generator Interface Panels like those made by Roam are also known in various industries under other names such as Generator Connector Panels, Tap Boxes, Inlet Boxes, Docking Stations, Generator Plugs, Gen Boxes, and Generator Quick Connects.Roam uses genuine Cooper Crouse-Hinds Cam-Lok brand connectors. Similar compatible connectors are sometimes referred to as "Cam-Lock" connectors by their manufacturers, distributors, and/or users.

• Single-phase power, at up to 200A

• 240 VAC, 480 VAC, & 600 VAC rated panels

• Spot-welded Galvanneal steel construction

• Custom labels & configurations available

• Brown-Orange-Yellow connectors at 480VAC

• Corrosion-resistant powder coating

• UV-resistant four color labels

• Built to NEMA 3R standard

• Internal and external grounding studs

• Four Male E1016 Cam-Lok connectors

MTC 6001 ESK2
MTC 6001 ESK2 - 200A/240VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Generator Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Generator Connector Panel - MTC6001ESK2 - UL/cUL Listed

MTC 6001 ESK2 - 200A/240VAC
Single-Phase - Generator Interface Panel - Open/240VAC

MTC 6001 ESK2
MTC 6001 ESK2 - 200A/240VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Generator Interface Box - 120VAC, 208VAC, 230VAC, & 240VAC - 240v (120v, 208v, 230v, & 240v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Generator Connector Panel - MTC6001ESK2 - UL/cUL Listed

MTC 6001 ESK2 - 200A/240VAC
Single-Phase - Generator Interface Panel - Closed/240VAC

Connections

Roam's MTC 6001 ESKv 200 Amp Generator Interface Boxes accept either #2 to 2/0 or 2/0 to 4/0 cables via Cam-Lock plugs on the generator cable side, and from 1/0 to 4/0 cables on the internal wireway side. 

Voltages up to 600VAC

Roam offers MTC 6001 ESKv Generator Panels in models that support up to 240 VAC (120v, 208v, 230v, 240v)—MTC 6001 ESK2, up to 480 VAC (277v, 330v, 440v, 480v)—MTC 6001 ESK4-BOY, and up to 600 VAC (575v, 577v, 600v)—MTC 6001 ESK6, which are UL Listed and cUL Listed (Canada) at those voltage levels. Brown-Orange color coding (for labels, Cam-Locks, & Cam-Lock spring caps) is normally used for most 480 VAC applications.

MTC 6001 ESK4-BOY
MTC 6001 ESK4-BOY - 200A/480VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Generator Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock - Generator Connector Panel - MTC6001ESK4-BOY - UL/cUL Listed

MTC 6001 ESK4-BOY - 200A/480VAC
Single-Phase - Generator Interface Panel - Open/480VAC

MTC 6001 ESK4-BOY
MTC 6001 ESK4-BOY - 200A/480VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Generator Interface Box - 277VAC, 330VAC, 440VAC, & 480VAC - 480v (277v, 330v, 440v, & 480v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Generator Connector Panel - MTC6001ESK4-BOY - UL/cUL Listed

MTC 6001 ESK4-BOY - 200A/480VAC
Single-Phase - Generator Interface Panel - Closed/480VAC

MTC 6001 ESK6
MTC 6001 ESK6 - 200A/600VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Open - Single-Phase - Generator Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Generator Connector Panel - MTC6001ESK6 - UL/cUL Listed

MTC 6001 ESK6 - 200A/60VAC
Single-Phase - Generator Interface Panel - Open/60VAC

MTC 6001 ESK6
MTC 6001 ESK6 - 200A/600VAC - 1-Phase - Generator Interface Panel - Connection Panel - Tap Box - Docking Station - Front View - Door Closed - Single-Phase - Generator Interface Box - 575VAC, 577VAC, & 600VAC - 600v (575v, 577v, & 600v) - 200 Amp - Door Open - Showing E1016 (J-Series/16-Series) Male Cam-Lok Connectors - Cam-Lock Generator Connector Panel - MTC6001ESK6 - UL/cUL Listed

MTC 6001 ESK6 - 200A/60VAC
Single-Phase - Generator Interface Panel - Closed/60VAC

Canadian Color Coding Available

Any Roam panels with power connectors normally color coded (for Cam-Locks, Spring Caps, and Labels) as L1=Black & L2=Red are also available in the typical Canadian color coding format of L1=Red & L2=Black. If you need to order a unit with the Canadian color scheme, just add a "-CAN" to the end of the Model Number. If the Generator you are connecting to uses the US color coding (L1=Black, L2=Red), then you may want the standard US color system (so long as local electrical codes allow).

Spring Caps

These units are also available without Cam-Lock Spring Caps. Roam strongly recommends the Spring Cap version to help protect the Cam-Lock connectors' brass conductors from insects, spider webs, dust, and corrosion. Omit the "K" from the model number to order a version of this panel without Spring Caps.

Model Numbers & Options

The "v" in the part number represents a code of either 2 (for up to 240 VAC panels), 4 (for up to 480 VAC panels), or 6 (for up to 600 VAC panels).

unnamed.png

UL 1008 Listed—US & Canada

bottom of page